Skip to main content

Label Maker Templets

Standard Scheme

Standards for naming and labeling networks and similar devices on installs.

Standard Example

Notes: 

  • All panels are counted clockwise from the North West corner of the building
Wire Labels:Inbetween Devices:

2x Layer labels.  Order of spanning tree.  Top of label = First location.   The bottom of the Label = end of the cable. 

Device InFire OutExample ExpansionExpansion/Options
Firewalls/RoutersDevice FW-01,FW-02

Top: Where it terminates

Bottom: What it terminates 

FW-01, FW-02


N/A


SwitchesISP to Firewall/Router SWF1-01, SW-IDF

ISP-## [Number or name]

FW-Primary-PORT


ISP-001

FW-Primary-WAN1


ISP-AT&T

FW-Secondary-WAN2

Router to Aggrate Switch

FW/ROUT-PORT-3

AGGR-##-PORT

FW-Primary-Port3

AGGR-01-Port1

FW-Secondary-Port3

AGGR-02-Port1

Patch Cables between IDF/MPOE and the environment NET-

(thing)-(floor)-(number)

Service*-###

NET | TEL | COM |

IDF-1-2

NET-001,001

NET-002

*TEL-001

IDF-1-2

NET-001a,001a

NET-001b
Riser Cables Front (thing)-(floor)-(number)
End (thing)-(floor)-(number)

IDF-1-1 | 001

PNL-2-2 | 001

IDF-1-1 | 001a, IDF-1-1 | 001b

PNL-1-2 | 002a

Badge Readers BGE-

(thing)-(floor)-(doornumber)

number)

DR##-BGR-##


PANEL-2-1

DR04-BGR-1


Camera Cable (thing)-(floor)-(number)
CAM-###

PANEL-1-1

CAM-001008


Access-Hub Ethernet(not in panel)

Access(thing)-(floor)-(number)

FL-PNL.###ACCESS-DR##

ACCESSPANEL-2-1

1-2.001ACCESS-DR04


Panels / Doors
Location/Type First Example Expansion
Main Point of Entry MPOE-(Floor.Panel Number) MPO-FL1-01 N/A - Only 1 MPOE per side
Intermediate Distribution Frame IDF-(Floor)-(Panel Number) IDF-1-1 IDF-1-1a, IDF-1-1b
Media Cabinets/Panels Panel-(Floor)-(Panel Number) Panel-1-1, Panel 2-1




Notes: 

MPOE - This is where the internet comes into the building.  In residential buildings, it is commonly seen as a utility closed hidden under stairs or basements.  In large commercial buildings, it's widely a Riser [cables that link IDFs in other floors or wings are called risers].  

IDF - This is where your switching or server equipment goes to support per floor.  This commonly hosts switches that connect back to the MPOE 

Controllers: Physical hardware in Panels, Walls or Mounted to walls
Location/Type First Example Expansion
Door Access Hub DOOR-(floor)-(door number) DOOR-1-7 DOOR-1-7a
Door Intercom IntCom-(floor)-(door) IntCom-1-1 IntCom
Door Reader
READER-(floor)-(door number)

READER-1-7

Network Devices:
Location/Type First Example Expansion
Firewall/Router (site)-FW## 925-FW01 925-FW02
Switches (site)-SW## 925-SW01 925-SW02
Cameras (location)-(object-in-camera) INTERNAL-CashReg INTERNAL-CashReg02








Notes:

Cameras have special naming schemes.  We define them as internal or external to quickly identify access.  Tenants and Employees typically can access external cameras, but internal camera access is heavily policed.   A camera overlooking a driveway would be called "EXTERNAL-Driveway-North"